I am using the flow control setting “RS485 Transceiver Control – Set RTS high while sending”. In Docklight V2.1 it does not set RTS to high like it did in Docklight V2.0.

I am using the flow control setting “RS485 Transceiver Control – Set RTS high while sending”. In Docklight V2.1 it does not set RTS to high like it did in Docklight V2.0.

Applies to: Docklight V2.1.10 / Docklight Scripting V2.1.10, Article ID: dl_prb039

This is a confirmed and fixed bug. When using Flow Control Option “RS485 Transceiver Control”, the “RTS high while sending” is not applied.

Reason: Unfortunately the September release V2.1.10 contained an unnoticed bug in a helper DLL. The bug passed our regression testing, since the testing script used DL.SetChannelSettings to switch the flow control setting “on the fly”, and this method actually worked correctly.

The current Docklight and Docklight Scripting setup packages have been corrected and tested against the bug.