When opening the “Project Settings” dialog, Docklight freezes for 20-30 seconds / appears to crash. How can I fix this?
Applies to: Docklight / Docklight Scripting V2.2.8 or earlier, Article ID: dl_prb049 One some rare COM port configurations, querying...
-
In my script, I used an invalid DL method call, which should produce a script execution error. But the script simply stops, without further error message.
Applies to: Docklight Scripting V2.2, Article ID: dl_prb050 This situation could appear if you write a script code line...
-
When I open the “Edit Send Sequence” or “Edit Receive Sequence” dialog and close it / move to a different sequence, Docklight asks if I want to keep the modification, even if I did not change anything.
Applies to: Docklight / Docklight Scripting V2.3.23, Article ID: dl_prb051 This is a UI glitch that seemed to have...
-
After enabling “Expert Options – External / High Priority Process”, Docklight cannot start communications and reports “Could not start external high priority process.”
Applies to: Docklight / Docklight Scripting V2.2, Article ID: dl_prb046 There is a bug in the V2.2.8 version and...
-
The Docklight E-Shop says “Unfortunately, due to legal constraints, we cannot ship the product to the country you have chosen”.
Applies to: Docklight Tap, Tap Pro, Tap 485, Monitoring Cable and RS232 Adapter, Article ID: dl_prb048 Docklight hardware accessories...
-
The display for the handshake signals RTS / DTR / CTS / DSR / DCD / RI is incorrect, resp. doesn’t seem to update immediately.
Applies to: Docklight / Docklight Scripting V2.3.23, Article ID: dl_prb052 When using Docklight Flow Control Support setting “Manual”, or...
-
I use DL.SetChannelSettings(“COMxx”) to check if my COM port is available, but I still receive an error when opening the port using DL.StartCommunication() (Windows Error #5 – Access is Denied).
Applies to: Docklight Scripting V2.3.26 or earlier, Article ID: dl_prb053 The DL.SetChannelSettings() does not perform the ‘open port’ test...
-
Windows does not install the driver automatically. How can I fix this?
Applies to: Docklight RS232 Adapter / Tap / Tap Pro / Tap 485, Article ID: dl_prb038 The default behavior...
-
I am using the flow control setting “RS485 Transceiver Control – Set RTS high while sending”. In Docklight V2.1 it does not set RTS to high like it did in Docklight V2.0.
Applies to: Docklight V2.1.10 / Docklight Scripting V2.1.10, Article ID: dl_prb039 This is a confirmed and fixed bug. When...
-
I have large Send and Receive Sequence lists in my Docklight projects and I want to prevent that they get accidently re-ordered by an unintended drag-and-drop.
Applies to: Docklight / Docklight Scripting (V2.1 or earlier), Article ID: dl_prb040 The current V2.2 versions of Docklight and...