Windows does not allow me to install and use the free com0com Virtual Null Modem driver from your FAQ. How can I fix this?
Applies to: Docklight / Docklight Scripting (all versions), Article ID: dl_prb059 There seems to be an issue with the...
-
When accessing a COM port, Docklight consumes a lot of CPU time (e.g. 25%), even if there is no communication. How can I fix this?
Applies to: Docklight V2.4.5 / Docklight Scripting V2.4.5, Article ID: dl_prb060 This seems to the a behavior that appears...
-
When starting Docklight, a Windows Installer windows appears. How can I fix this?
Applies to: Docklight / Docklight Scripting (all versions), Article ID: dl_prb045 On isolated Windows computers, and especially after a...
-
When using ASCII codes above 127 (Hex 7F) in the Edit Send Sequence or Edit Receive sequence dialog, Docklight changes these to 7F after switching to ASCII representation and back to Hex.
Applies to: Docklight / Docklight Scripting V2.2.8 or earlier, Article ID: dl_prb047 This is unfortunately a problem that can...
-
When opening the “Project Settings” dialog, Docklight freezes for 20-30 seconds / appears to crash. How can I fix this?
Applies to: Docklight / Docklight Scripting V2.2.8 or earlier, Article ID: dl_prb049 One some rare COM port configurations, querying...
-
In my script, I used an invalid DL method call, which should produce a script execution error. But the script simply stops, without further error message.
Applies to: Docklight Scripting V2.2, Article ID: dl_prb050 This situation could appear if you write a script code line...
-
When I open the “Edit Send Sequence” or “Edit Receive Sequence” dialog and close it / move to a different sequence, Docklight asks if I want to keep the modification, even if I did not change anything.
Applies to: Docklight / Docklight Scripting V2.3.23, Article ID: dl_prb051 This is a UI glitch that seemed to have...
-
After enabling “Expert Options – External / High Priority Process”, Docklight cannot start communications and reports “Could not start external high priority process.”
Applies to: Docklight / Docklight Scripting V2.2, Article ID: dl_prb046 There is a bug in the V2.2.8 version and...
-
The Docklight E-Shop says “Unfortunately, due to legal constraints, we cannot ship the product to the country you have chosen”.
Applies to: Docklight Tap, Tap Pro, Tap 485, Monitoring Cable and RS232 Adapter, Article ID: dl_prb048 Docklight hardware accessories...
-
The display for the handshake signals RTS / DTR / CTS / DSR / DCD / RI is incorrect, resp. doesn’t seem to update immediately.
Applies to: Docklight / Docklight Scripting V2.3.23, Article ID: dl_prb052 When using Docklight Flow Control Support setting “Manual”, or...