When I open the “Edit Send Sequence” or “Edit Receive Sequence” dialog and close it / move to a different sequence, Docklight asks if I want to keep the modification, even if I did not change anything.
Applies to: Docklight / Docklight Scripting V2.3.23, Article ID: dl_prb051 This is a UI glitch that seemed to have...
-
The display for the handshake signals RTS / DTR / CTS / DSR / DCD / RI is incorrect, resp. doesn’t seem to update immediately.
Applies to: Docklight / Docklight Scripting V2.3.23, Article ID: dl_prb052 When using Docklight Flow Control Support setting “Manual”, or...
-
I use DL.SetChannelSettings(“COMxx”) to check if my COM port is available, but I still receive an error when opening the port using DL.StartCommunication() (Windows Error #5 – Access is Denied).
Applies to: Docklight Scripting V2.3.26 or earlier, Article ID: dl_prb053 The DL.SetChannelSettings() does not perform the ‘open port’ test...
-
I use Docklight Tap (or: Docklight Tap Pro, Docklight Tap 485, Docklight RS232 Adapter) on Windows 10. If I open a second standard COM port device, the Tap hardware stops working, or Windows 10 even restarts.
Applies to: Docklight Tap, Docklight Tap Pro, Docklight Tap 485 or Docklight RS232 Adapter, Article ID: dl_prb054 Only in...
-
After enabling “Expert Options – External / High Priority Process”, Docklight cannot start communications and reports “Could not start external high priority process.”
Applies to: Docklight / Docklight Scripting V2.2, Article ID: dl_prb046 There is a bug in the V2.2.8 version and...
-
When I use Docklight V2.3 with my COM device, I receive periodic error messages “Docklight reports: General I/O error on COM…”. In Docklight V2.2 this does not happen. How can I make Docklight V2.3 work with my device?
Applies to: Docklight / Docklight Scripting V2.3, Article ID: dl_prb055 Docklight V2.3 introduced additional error checking which seems to...
-
I entered the license key, but Docklight still is in evaluation mode. How do I fix this?
Applies to: Docklight (all versions), Article ID: dl_prb031 Some users have reported that Docklight does not keep the license...
-
I have large Send and Receive Sequence lists in my Docklight projects and I want to prevent that they get accidently re-ordered by an unintended drag-and-drop.
Applies to: Docklight / Docklight Scripting (V2.1 or earlier), Article ID: dl_prb040 The current V2.2 versions of Docklight and...
-
The Docklight dialog fonts seem to be too large / the font scaling and layout is wrong. The texts are cut off and some dialog elements are unreadable.
Applies to: Docklight / Docklight Scripting V2.0.5 or earlier, Article ID: dl_prb035 On singular Windows 7/8/10 installations there seems...
-
I am trying to open a USB HID connection, but I cannot get it to work.
Applies to: Docklight Scripting (V2.2 and higher), Article ID: dl_prb041 On Windows 11/Windows 10 some details about USB HID...